FF130 Downlight Protection Cone
Thermal Loft Cone
PRODUCT HIGHLIGHTS
Downlight without FF130
Downlight with FF130
Recessed
downlights are used in many Australian homes and businesses. Although
they give the attractive crisp white light which makes them very popular,
they also represent a potential fire hazard, especially when buried
in loft insulation.
Numerous house fires have been caused by the ignition of combustibles in ceiling spaces caused by hot downlights being mistakenly covered with loft insulation and for this reason the regulation for fitting downlights has been tightened, this legislation is covered by AS/NZS 3000:2007.
TENMAT is known worldwide for the development and manufacture of fire protection products. To meet the needs of AS/NZS 3000:2007 and also allow a product to be fitted from below the ceiling, TENMAT has developed the Thermal Loft Cone.
The FF130 Thermal Loft Cone meets the latest needs of AS/NZS 3000:2007 and international test standards for a lighting product when covered with insulation. In addition, it adheres to the maximum external temperatures requested by the Australian Technical Regulator.
The Thermal Loft Cone has been developed to reduce the risk of fire caused by the overheating of downlights.
The fire resistant Thermal Loft Cones ensure that insulation and combustibles are kept away from the downlight when installed in loft spaces.
The difference in a downlight with and without a Thermal Loft Cone can be seen via thermal image photography on the right, in particular see how the excessive heat of a downlight could be a possible point of ignition.
The FF130 Downlight Protection Cone is suitable for downlights with cut-out dimensions of 75 - 100mm.
Internal Height 220mm
Internal Diameter 220mm
For Pricing and Availability click here.
BENEFITS
- Reduces the risk of fire by keeping combustibles away from hot downlight.
- Fully tested to prevent overheating.
- Energy Saving.
- Minimizes heat loss into roof space.
- Creates a Thermal Barrier.
- Can be fitted from above or below the ceiling.
- Improves air tightness of the room and limits draft.
- Lightweight - Does not overload the ceiling.
- Easy to fit without special tools.
- Firefly materials withstands temperatures of +1000 °C.
- Can be fitted tightly against ceiling joists.
- Suitable for low and mains voltage fittings.
- Easy to remove and re-install for fixture maintenance.
- Enhances the acoustic protection of the ceiling.
- Maintenance free.
View
FF130 Data Sheet
View
FF130 Installation Instruction
View
AS 60598.1 and A 60598.2.2 Test Report
View
Independent Energy Efficiency Report
View
Airtightness Report